{"content":[{"cattype":"product_txt","name":"Product Texts","content":"Vydyne R530H NAT is a general purpose, 30% glass-filled, heat-stabilized, high viscosity PA66 based resin designed for injection molding applications. R530H NAT offers standard flow with a natural surface finish and maintains the excellent resistance typical of PA66 in chemicals, machine and motor oils, solvents, and gasoline.","protectxt":"","type":"Text"},{"fname":"Additive","content":["Heat Stabilizer","Lubricant"],"cattype":"features","name":"General","type":"Feature"},{"fname":"Features","content":["Antifreeze Resistant","Chemical Resistant","Fatigue Resistant","Gasoline Resistant","Good Flow","Heat Stabilized","Lubricated","Solvent Resistant"],"cattype":"features","name":"General","type":"Feature"},{"fname":"Uses","content":["Glass Reinforced"],"cattype":"features","name":"General","type":"Feature"},{"fname":"Agency Rating","content":["ASTM, D4066 PA012G30","ASTM, D6779 PA012G30","FDA, 21 CFR 177.1500","EU, 2023\/2006","EU, 10\/2011","EC, 1935\/2004"],"cattype":"features","name":"General","type":"Feature"},{"fname":"Automotive Specifications","content":["GM GMW3038P-PA66-GF30H","Toyota TSM5603G, Class 2B, Rev 5 (compliance)","Tesla TM-1006 v3 - 301130","Tesla TM-1006 v3 - 201130","Tesla TM-1006 v3 - 101130","Mercedes-Benz DBL5406-PV21 (compliance)","Mahle SD2-181 (AR.06576) Rev. 7","GM GMW3038P-PA66-GF30J","GM GMW16270P-PA66-GF30","Ford WSS-M4D752-B1 ","Chery Motor Q-SQR.S1-33-2012 CMP.PA66.G6","Aisin TO20141124 - P-PA66-GF30-807","VW TL 52682 (compliance)"],"cattype":"features","name":"General","type":"Feature"},{"fname":"UL File Number","content":["E70062"],"cattype":"features","name":"General","type":"Feature"},{"fname":"Appearance","content":["Natural Color"],"cattype":"features","name":"General","type":"Feature"},{"fname":"Forms","content":["Pellets"],"cattype":"features","name":"General","type":"Feature"},{"fname":"Processing Method","content":["Injection Molding"],"cattype":"features","name":"General","type":"Feature"},{"name":"Physical","namev":"dry\/cond.","groups":[{"content":[{"name":"Density","options":[],"unit":"g\/cm\u00b3","standard":"ISO 1183","value":"1.37\/-","tabbed":0},{"name":"Molding Shrinkage","options":[],"unit":"","standard":"ISO 294-4","value":"","tabbed":0},{"name":"Across Flow : 23\u00b0C, 2.00 mm","options":[],"unit":"%","standard":"ISO 294-4","value":"0.9\/*","tabbed":1},{"name":"Flow : 23\u00b0C, 2.00 mm","options":[],"unit":"%","standard":"ISO 294-4","value":"0.4\/*","tabbed":1},{"name":"Water Absorption","options":[],"unit":"","standard":"ISO 62","value":"","tabbed":0},{"name":"23\u00b0C, 24 hr","options":[],"unit":"%","standard":"ISO 62","value":"0.9\/*","tabbed":1},{"name":"Equilibrium, 23\u00b0C, 50% RH","options":[],"unit":"%","standard":"ISO 62","value":"1.9\/*","tabbed":1}],"emptyUnit":false,"emptyStd":false}],"type":"Spt"},{"name":"Mechanical","namev":"dry\/cond.","groups":[{"content":[{"name":"Tensile Modulus (23\u00b0C)","options":[],"unit":"psi","standard":"ISO 527-2","value":"1.45E6\/1.07E6","tabbed":0},{"name":"Tensile Stress (Break, 23\u00b0C)","options":[],"unit":"psi","standard":"ISO 527-2","value":"28300\/19600","tabbed":0},{"name":"Tensile Strain (Break, 23\u00b0C)","options":[],"unit":"%","standard":"ISO 527-2","value":"3\/5","tabbed":0},{"name":"Flexural Modulus (23\u00b0C)","options":[],"unit":"psi","standard":"ISO 178","value":"1.39E6\/870000","tabbed":0},{"name":"Flexural Strength (23\u00b0C)","options":[],"unit":"psi","standard":"ISO 178","value":"39200\/27600","tabbed":0},{"name":"Poisson's Ratio (23\u00b0C)","options":[],"unit":"","standard":"ISO 527-2","value":"0.4","tabbed":0}],"emptyUnit":false,"emptyStd":false}],"type":"Spt"},{"name":"Impact","namev":"dry\/cond.","groups":[{"content":[{"name":"Charpy Notched Impact Strength","options":[],"unit":"","standard":"ISO 179\/1eA","value":"","tabbed":0},{"name":"+23\u00b0C","options":[],"unit":"ftlb\/in\u00b2","standard":"ISO 179\/1eA","value":"5.23\/6.18","tabbed":1},{"name":"-30\u00b0C","options":[],"unit":"ftlb\/in\u00b2","standard":"ISO 179\/1eA","value":"4.76\/5.23","tabbed":1},{"name":"Charpy Unnotched Impact Strength","options":[],"unit":"","standard":"ISO 179\/1eU","value":"","tabbed":0},{"name":"+23\u00b0C","options":[],"unit":"ftlb\/in\u00b2","standard":"ISO 179\/1eU","value":"35.7\/40.4","tabbed":1},{"name":"-30\u00b0C","options":[],"unit":"ftlb\/in\u00b2","standard":"ISO 179\/1eU","value":"30.9\/38.1","tabbed":1},{"name":"Notched Izod Impact Strength","options":[],"unit":"","standard":"ISO 180\/1A","value":"","tabbed":0},{"name":"+23\u00b0C","options":[],"unit":"ftlb\/in\u00b2","standard":"ISO 180\/1A","value":"5.71\/6.18","tabbed":1},{"name":"-30\u00b0C","options":[],"unit":"ftlb\/in\u00b2","standard":"ISO 180\/1A","value":"4.76\/5.23","tabbed":1}],"emptyUnit":false,"emptyStd":false}],"type":"Spt"},{"name":"Thermal","namev":"dry\/cond.","groups":[{"content":[{"name":"Heat Deflection Temperature","options":[],"unit":"","standard":"ISO 75-2\/A","value":"","tabbed":0},{"name":"1.80 MPa, Unannealed","options":[],"unit":"\u00b0F","standard":"ISO 75-2\/A","value":"482\/-","tabbed":1},{"name":"0.45 MPa, Unannealed","options":[],"unit":"\u00b0F","standard":"ISO 75-2\/B","value":"500\/-","tabbed":1},{"name":"Melting Temperature","options":[],"unit":"\u00b0F","standard":"ISO 11357-3","value":"500\/*","tabbed":0},{"name":"CLTE","options":[],"unit":"","standard":"ISO 11359-2","value":"","tabbed":0},{"name":"Flow : 23 to 55\u00b0C, 2.00 mm","options":[],"unit":"E-6\/K","standard":"ISO 11359-2","value":"22\/*","tabbed":1},{"name":"Transverse : 23 to 55\u00b0C, 2.00 mm","options":[],"unit":"E-6\/K","standard":"ISO 11359-2","value":"107\/*","tabbed":1},{"name":"RTI Elec","options":[],"unit":"","standard":"UL 746","value":"","tabbed":0},{"name":"0.750 mm","options":[],"unit":"\u00b0F","standard":"UL 746","value":"284","tabbed":1},{"name":"1.50 mm","options":[],"unit":"\u00b0F","standard":"UL 746","value":"284","tabbed":1},{"name":"3.00 mm","options":[],"unit":"\u00b0F","standard":"UL 746","value":"284","tabbed":1},{"name":"RTI Imp","options":[],"unit":"","standard":"UL 746","value":"","tabbed":0},{"name":"0.750 mm","options":[],"unit":"\u00b0F","standard":"UL 746","value":"248","tabbed":1},{"name":"1.50mm","options":[],"unit":"\u00b0F","standard":"UL 746","value":"248","tabbed":1},{"name":"3.00 mm","options":[],"unit":"\u00b0F","standard":"UL 746","value":"248","tabbed":1},{"name":"RTI Str","options":[],"unit":"","standard":"UL 746","value":"","tabbed":0},{"name":"0.750 mm","options":[],"unit":"\u00b0F","standard":"UL 746","value":"257","tabbed":1},{"name":"1.50 mm","options":[],"unit":"\u00b0F","standard":"UL 746","value":"284","tabbed":1},{"name":"3.00 mm","options":[],"unit":"\u00b0F","standard":"UL 746","value":"284","tabbed":1}],"emptyUnit":false,"emptyStd":false}],"type":"Spt"},{"name":"Electrical","namev":"dry\/cond.","groups":[{"content":[{"name":"Volume Resistivity (1.00 mm)","options":[],"unit":"Ohm*m","standard":"IEC 60093","value":"1E11\/-","tabbed":0},{"name":"Dielectric Strength (1.00 mm)","options":[],"unit":"kV\/in","standard":"IEC 60243","value":"508\/-","tabbed":0},{"name":"Arc Resistance (3.00 mm)","options":[],"unit":"","standard":"ASTM D 495","value":"6","tabbed":0},{"name":"High Amp Arc Ignition (HAI)","options":[],"unit":"","standard":"UL 746","value":"","tabbed":0},{"name":"0.750 mm","options":[],"unit":"","standard":"UL 746","value":"PLC 0","tabbed":1},{"name":"1.50 mm","options":[],"unit":"","standard":"UL 746","value":"PLC 0","tabbed":1},{"name":"3.00 mm","options":[],"unit":"","standard":"UL 746","value":"PLC 0","tabbed":1},{"name":"High Voltage Arc Tracking Rate (HVTR), 3.00 mm","options":[],"unit":"","standard":"UL 746","value":"PLC 1","tabbed":0},{"name":"Hot-wire Ignition (HWI)","options":[],"unit":"","standard":"UL 746","value":"","tabbed":0},{"name":"0.750 mm","options":[],"unit":"","standard":"UL 746","value":"PLC 4","tabbed":1},{"name":"1.50 mm","options":[],"unit":"","standard":"UL 746","value":"PLC 3","tabbed":1},{"name":"3.00 mm","options":[],"unit":"","standard":"UL 746","value":"PLC 4","tabbed":1}],"emptyUnit":false,"emptyStd":false}],"type":"Spt"},{"name":"Flammability","namev":"Value","groups":[{"content":[{"name":"Burning Rate, 2.00 mm","options":[],"unit":"in\/min","standard":"ISO 3795","value":"0","tabbed":0},{"name":"Flammability","options":[],"unit":"","standard":"UL 94","value":"","tabbed":0},{"name":"0.750 mm","options":[],"unit":"","standard":"UL 94","value":"HB","tabbed":1},{"name":"1.50 mm","options":[],"unit":"","standard":"UL 94","value":"HB","tabbed":1},{"name":"3.00 mm","options":[],"unit":"","standard":"UL 94","value":"HB","tabbed":1},{"name":"Glow Wire Flammability Index","options":[],"unit":"","standard":"IEC 60695-2-12","value":"","tabbed":0},{"name":"0.750 mm","options":[],"unit":"\u00b0F","standard":"IEC 60695-2-12","value":"1250","tabbed":1},{"name":"1.50 mm","options":[],"unit":"\u00b0F","standard":"IEC 60695-2-12","value":"1250","tabbed":1},{"name":"3.00 mm","options":[],"unit":"\u00b0F","standard":"IEC 60695-2-12","value":"1250","tabbed":1},{"name":"Glow Wire Ignition Temperature","options":[],"unit":"","standard":"IEC 60695-2-13","value":"","tabbed":0},{"name":"0.750 mm","options":[],"unit":"\u00b0F","standard":"IEC 60695-2-13","value":"1290","tabbed":1},{"name":"1.50 mm","options":[],"unit":"\u00b0F","standard":"IEC 60695-2-13","value":"1290","tabbed":1},{"name":"3.00 mm","options":[],"unit":"\u00b0F","standard":"IEC 60695-2-13","value":"1290","tabbed":1}],"emptyUnit":false,"emptyStd":false}],"type":"Spt"},{"name":"Injection","namev":"Value","groups":[{"content":[{"name":"Drying Temperature","options":[],"unit":"\u00b0F","standard":"","value":"176","tabbed":0},{"name":"Drying Time","options":[],"unit":"h","standard":"","value":"4","tabbed":0},{"name":"Rear Temperature","options":[],"unit":"\u00b0F","standard":"","value":"536 - 590","tabbed":0},{"name":"Middle Temperature","options":[],"unit":"\u00b0F","standard":"","value":"536 - 590","tabbed":0},{"name":"Front Temperature","options":[],"unit":"\u00b0F","standard":"","value":"536 - 590","tabbed":0},{"name":"Nozzle temperature","options":[],"unit":"\u00b0F","standard":"","value":"536 - 590","tabbed":0},{"name":"Processing (Melt) Temperature","options":[],"unit":"\u00b0F","standard":"","value":"545 - 581","tabbed":0},{"name":"Mold Temperature","options":[],"unit":"\u00b0F","standard":"","value":"149 - 203","tabbed":0}],"emptyUnit":false,"emptyStd":true}],"type":"Spt"},{"name":"Injection","namev":"Value","groups":[{"content":[{"name":"Drying Temperature","options":[],"unit":"\u00b0F","standard":"","value":"176","tabbed":0},{"name":"Drying Time","options":[],"unit":"h","standard":"","value":"4","tabbed":0},{"name":"Rear Temperature","options":[],"unit":"\u00b0F","standard":"","value":"536 - 590","tabbed":0},{"name":"Middle Temperature","options":[],"unit":"\u00b0F","standard":"","value":"536 - 590","tabbed":0},{"name":"Front Temperature","options":[],"unit":"\u00b0F","standard":"","value":"536 - 590","tabbed":0},{"name":"Nozzle temperature","options":[],"unit":"\u00b0F","standard":"","value":"536 - 590","tabbed":0},{"name":"Processing (Melt) Temperature","options":[],"unit":"\u00b0F","standard":"","value":"545 - 581","tabbed":0},{"name":"Mold Temperature","options":[],"unit":"\u00b0F","standard":"","value":"149 - 203","tabbed":0}],"emptyUnit":false,"emptyStd":true}],"type":null,"content":[]}],"general":{"name":"Vydyne\u00ae R530H NAT","abbt":"PA66-GF30","pname":"Ascend","pshortname":"Ascend","pid":1,"issue_date":null,"region":[],"polymer":"polyamide 66","assortment_name":"VYDYNE\u00ae PA66","assortment_color":"","lastchange":"2026-04-30","prod_status":"current","moisturedep":1,"polymer2":""},"id":"607","injds":false,"psds":false,"bmds":false,"extrds":false,"eqds":false,"ris":false}